All
  • Products
    • Testing Supplies
      • Benchtop/Handheld Meters
      • Lab Supplies
      • Reagents & Standards
      • Test Kits
      • Custom Test Kits
      • Custom Packaging
    • Feed & Control Equipment
      • Containment Tanks
      • Panels & Pre-Built Systems
      • Controllers & Accessories
      • Pumps & Accessories
      • Sensors & Probes
    • Software & Technology
      • Service Management Software
      • Modems
      • Panel Builder
      • Remote Tank Monitoring
    • Education
      • Custom Curriculum Kits
      • Classroom Ready Kits
  • Services
    • Training
      • AquaPhoenix Academy
      • Training Kits
      • Webinars
    • Custom
      • Custom Packaging & Fulfillment
      • Custom Test Kits
      • Dropshipping
      • Research & Development
      • Inventory Management
    • Manufacturing
      • Private Label Chemical
      • Chemical & Reagent
      • Panel Fabrication
      • ISO Certified
    • Integration
      • Service Management Software
      • Software & Devices
  • Industries
    • Industrial Water Treatment
      • Power Generation
      • Pulp & Paper
      • Wastewater
      • Water Conditioning
    • Food & Beverage
      • Cleaning & Sanitation
      • Breweries
      • Food Packaging
      • Bottling
      • Dairy
    • Environmental
      • Stormwater
      • Agriculture
      • Aquaculture
    • Oil & Gas
      • Chemical Processing
      • Fracturing
    • Additional Applications
      • Quality Control
      • Lab/Clinical
      • Pools & Spas
  • Company
    • About
    • News
    • Resources
    • Careers
    • FAQ’s
    • Contact Us
  • Careers

Products

Chemical Oxygen Demand (COD) Testing

Products

  • Testing Supplies
    • Benchtop/Handheld Meters
    • Lab Supplies
    • Reagents & Standards
    • Test Kits
    • Custom Test Kits
    • Custom Packaging
  • Feed & Control Equipment
    • Containment Tanks
    • Panels & Pre-Built Systems
    • Controllers & Accessories
    • Pumps & Accessories
    • Sensors & Probes
  • Software & Technology
    • Service Management Software
    • Modems
    • Panel Builder
    • Remote Tank Monitoring
  • Education
    • Custom Curriculum Kits
    • Classroom Ready Kits

Chemical Oxygen Demand (COD) Vials

Shop Now

Chemical Oxygen Demand (COD) is an analytical method which indirectly measures the amount of oxygen required to oxidize the organic matter in a water sample. The higher the concentration of organic compounds in the sample, the greater the COD measurement will be.

Chemical Oxygen Demand is a key metric in the wastewater industry and is typically reported as milligrams of oxygen consumed per liter of sample (mg/L COD).

Why Measure Chemical Oxygen Demand?

There are two common reasons to measure COD in a wastewater facility:

  • To protect the environment and prevent getting fined.

Environmental regulatory agencies establish COD limits for wastewater facilities that discharge treated waste to receiving bodies of water. Exceeding these limits can lead to harsh fines or other penalties. If wastewater containing high COD levels is discharged into a natural body of water, the organic contaminants may consume or react with dissolved oxygen leading to dangerously low levels of oxygen, also known as hypoxia. This condition can stress or outright kill aquatic life.

  • To maximize the efficiency of the plant and lower costs.

A COD test can be used to assess the incoming influent quality so operators can react to shifting waste load conditions. This ensures the most efficient treatment processes are being used to lower costs and to ensure that the effluent is within the permit limits prior to discharge.

How do Chemical Oxygen Demand Tests Work?

There are a few standardized methods for measuring COD, but the most common is the dichromate reactor digestion method which involves the reaction of sample with potassium dichromate in a sulfuric acid solution.

The dichromate COD reagent is commonly sold in a sealed vial. Sample is added to the vial, and the reaction occurs during a digestion where the sample is heated for two hours at 150oC. As dichromate ion oxidizes organic matter in the sample, it is reduced to chromic ion, which is reflected by a change in color from orange or yellow to green. The sample is then read in a photometer or spectrophotometer to measure the change in color.

Shop COD

COD Products

Shop COD Products

K-7355 Low Range COD Vials (150 vials)

The K-7355 kit comes in a cardboard box and contains 150 vials, enough to perform up to 149 tests, and instruction book.

$208.00

K-7360S High Range COD Vials

The K-7360S kit comes in a cardboard box and contains 25 vials, enough to perform up to 24 tests, and instruction book.

$41.99

What's Included in a Chemical Oxygen Demand Test Kit?

A COD test kit commonly contains sealed vials that contain COD test reagent. Sample is dosed into the vials, resealed, and then digested. To perform a COD test, a digestor (sometimes called a digestor block) is required to heat the vials. Digestors are sold separately from the test kits. A photometer or spectrophotometer is also required and sold separately unless specifically stated.

Need help
finding something?

We are here for all your support inquiries and sales requests

Get in touch
blue AquaPhoenix logo

We’re here to help

Contact Us:
866-632-1291
Mon-Fri: 8am-6pm EST

Worldwide Distributors

Local:

717-632-1291

Toll-free:

866-632-1291

Contact Us:

Address

AquaPhoenix Scientific
860 Gitts Run Road Hanover, PA 17331

white AquaPhoenix logo

© 2024 AquaPhoenix. All rights reserved.

  • Products
  • Services
  • Industries
  • About us
  • Privacy policy
  • Terms & Conditions